FREDDOX FILTER DRIER SOLID CORE -DSC414S 1/2" ODF

FREDDOX

Product number: FFD2013
National Stock:
PLEASE LOGIN TO SEE PRICES
Product Group : Freddox Filter Drier
Absorption Capacity R134a 24°C [g H2O] : 103.2 kW
Absorption Capacity R134a 52°C [g H2O] : 89 kW
Absorption Capacity R404A/R507 24°C [g H2O] : 105.5 kW
Absorption Capacity R404A/R508 52°C [g H2O] : 98 kW
Absorption Capacity R407C 24°C [g H2O] : 84.5 kW
Absorption Capacity R407C 52°C [g H2O] : 68.1 kW
Absorption Capacity R410A 24°C [g H2O] : 92 kW
Absorption Capacity R410A 52°C [g H2O] : 74.1
Body Material : Steel
Connection Material : Copper
Connection Size : 1/2 in, 12 mm
Connection Type : Solder, ODF
Cooling Capacity ∆P 0.07 Bar R32 : 58.68 kW
Cooling Capacity ∆P 0.07 Bar R134a : 38.05 kW
Cooling Capacity ∆P 0.07 Bar R404A : 27.14 kW
Cooling Capacity ∆P 0.07 Bar R407C : 39.21 kW
Cooling Capacity ∆P 0.07 Bar R410A : 40.21 kW
Cooling Capacity ∆P 0.07 Bar R448A : 36.18 kW
Cooling Capacity ∆P 0.07 Bar R449A : 35.69 kW
Cooling Capacity ∆P 0.07 Bar R450A : 30.37 kW
Cooling Capacity ∆P 0.07 Bar R452A : 27.47 kW
Cooling Capacity ∆P 0.07 Bar R507A : 26.35 kW
Cooling Capacity ∆P 0.07 Bar R1234yf : 27.59 kW
Cooling Capacity ∆P 0.07 Bar R1234ze : 33.61 kW
Diameter : 89 mm
Drying Capacity R134a 24°C [kg refrigerant] : 110.97
Drying Capacity R134a 52°C [kg refrigerant] : 95.70
Drying Capacity R404A/R507 24°C [kg refrigerant] : 113.44
Drying Capacity R404A/R507 52°C [kg refrigerant] : 105.38
Drying Capacity R407C 24°C [kg refrigerant] : 90.86
Drying Capacity R407C 52°C [kg refrigerant] : 73.23
Drying Capacity R410A 24°C [kg refrigerant] : 98.92
Drying Capacity R410A 52°C [kg refrigerant] : 79.68
Inlet Connection Size : 1/2 in, 12.7 mm
Inlet Type : Soldering
Length : 238 mm
Max Pressure : 47 Bar
Model Number : DSC414S
Outlet Connection Size : 1/2 in, 12.7 mm
Outlet Type : Soldering
Product Group : Freddox Filter Drier
Refrigerant : HC, HFC, HFO
Temperature Range : -40-80 °C
Type : FILTER DRIER
Weight : 2.000 kg
Description
Freddox filter driers offer a high level of protection for refrigeration and air-conditioning systems liquid Line. They are specifically designed to capture and retain moisture and solid particles from circulating throughout the system, which can create acid that causes damage to the compressor and other components piped within the circuit. Freddox driers are available in version to be brazed (DSC S), or screwed with male/male (DSC) or female/male (DSC FM) SAE connexions to answer every configuration of installations .
Contact us for more information
File name Extension Size
Technical literature pdf 3.38 MB
Brochures pdf 870.76 KB
User Manual pdf 476.04 KB
User Manual pdf 1.87 MB